MANTIS 1

MANTIS 1

Dome protection system engineered to counter strike FPV drones within the 700–1020 MHz range.

[0.1] Key Specifications

Jamming radius

Jamming radius

100 - 300 m

Frequency range

Frequency range

720 - 1020 MHz

Omnidirectional coverage

360

0

The system is designed to protect both stationary and mobile assets.

Contact us for a consultation

[0.2] Scope of Application

Primary application: Vehicles and light armored vehicles (LAVs)

[0.3] System Components

The system consists of three separate functional units that operate together as a single entity, but can function independently if required.

[0.4] Detailed Specifications

Operating frequency range

Unit 1

Unit 2

Unit 3

720-850

MHz

840-950

MHz

930-1020

MHz

Number of RF channels

2

units

RF jamming bandwidth

Unit 1

Unit 2

Unit 3

130

MHz

110

MHz

90

MHz

Antenna radiation pattern

(wideband antenna system module)

Upper hemisphere, horizontal and vertical polarizations

Upper hemisphere, horizontal and vertical polarizations

Upper hemisphere, horizontal and vertical polarizations

Voltage Standing Wave Ratio (VSWR)

1,7

Output power per jamming channel

50 W

+/- 10%

+/- 10%

Effective jamming range

100–300 m

Targeted protocols

ExpressLRS, TBS Crossfire, and modifications

ExpressLRS, TBS Crossfire, and modifications

Reliability rating (MTBF)

800

hours

Crew required

2 personnel

Cooling System

Cooling system type

Active cooling

Active cooling

Number of fans per unit

2 (pcs)

Fan speed range

500 - 10000 (rpm)

Airflow

174 (m³/h)

/

102 CFM

Environmental Specifications

Ingress Protection rating

IP56

Operating temperature range

-20 ~ +50 (°C)

Atmospheric pressure

760 (mmHg)

Precipitation resistance

Snow, rain, and fog resistant

Snow, rain, and fog resistant

Max operational wind speed

30 (m/s)

Continuous operating time via

Vehicle power system

Continuous (with vehicle engine running)

Continuous (with vehicle engine running)

External battery (24V, 200Ah)

2 hours

2 hours

Minimum recommended battery specifications:

24V, ~200Ah, with an Ingress Protection rating of at least IP56 in accordance with DSTU IEC 60529

24V, ~200Ah, with an Ingress Protection rating of at least IP56 in accordance with DSTU IEC 60529

Power Supply System

Power supply type

External (via 24V, 80Ah external battery and/or generator)

External (via 24V, 80Ah external battery and/or generator)

Зовнішня (від зовнішнього акумулятора 24В, 80А·год

та/або генератора)

Operating voltage

12-24 (V)

Rated DC current consumption

75 А (12V)

Installation and connection on the protected asset

System deployment time

10 (min)

Weight

Total gross weight

72(kg)

Weight per individual unit

12,5 (kg)

Dimensions

Dimensions in transit packaging (L/W/H)

Габарити комплекса в транспортній упаковці

(Д/Ш/В)

600/400/250 (mm)

Including mounting system

1100/500/700 (mm)

1100/500/700 (mm)